Archive for the 'Colocalization' Category

cellular and subcelular co-localization analysis in light microscopy

Curr Protoc Cell Biol. 2008 Jun;Chapter 4:Unit 4.19.

Quantitative colocalization analysis of confocal fluorescence microscopy images.

Department of Anatomy and Cell Biology, Kochi University, Faculty of Medicine, Japan.

Colocalization is an important finding in many cell biological studies. This unit describes a protocol for quantitative evaluation of images with colocalization based on the calculation of a number of specialized coefficients. First, images of double-stained sections are subjected to background correction. Then, various coefficients are calculated. Meanings of the coefficients and a guide to interpretation of their results indicating either presence or absence of colocalization are given. Success in colocalization studies depends on the quality of analyzed images, proper preparation of them for coefficients calculations, and correct interpretation of obtained results. This protocol helps to ensure reliability of colocalization coefficients calculations. Copyright 2008 by John Wiley & Sons, Inc.

Zinchuk V, Zinchuk O.

Abstract

Quantitative colocalization analysis of confocal fluorescence microscopy images.
Curr Protoc Cell Biol. 2008 Jun;Chapter 4:Unit 4.19.
PMID: 18551422 [PubMed – in process]
2:

Comeau JW, Kolin DL, Wiseman PW.

Abstract

Accurate measurements of protein interactions in cells via improved spatial image cross-correlation spectroscopy.
Mol Biosyst. 2008 Jun;4(6):672-85. Epub 2008 Apr 16.
PMID: 18493666 [PubMed – in process]
3:
Abstract

Immunohistochemical localization of proteins in the nervous system.
Curr Protoc Neurosci. 2004 Feb;Chapter 1:Unit 1.2.
PMID: 18428596 [PubMed – indexed for MEDLINE]
4:

Scriven DR, Lynch RM, Moore ED.

Abstract

Image acquisition for colocalization using optical microscopy.
Am J Physiol Cell Physiol. 2008 May;294(5):C1119-22. Epub 2008 Mar 19.
PMID: 18353895 [PubMed – in process]
5:

Das R, Hammond S, Holowka D, Baird B.

Abstract

Real-time cross-correlation image analysis of early events in IgE receptor signaling.
Biophys J. 2008 Jun;94(12):4996-5008. Epub 2008 Mar 7.
PMID: 18326662 [PubMed – indexed for MEDLINE]
6:

Kandela IK, Bleher R, Albrecht RM.

Abstract

Immunolabeling for correlative light and electron microscopy on ultrathin cryosections.
Microsc Microanal. 2008 Apr;14(2):159-65. Epub 2008 Mar 3.
PMID: 18312726 [PubMed – indexed for MEDLINE]
7:

Reissig CJ, Rabin RA, Winter JC, Dlugos CA.

Abstract

d-LSD-induced c-Fos expression occurs in a population of oligodendrocytes in rat prefrontal cortex.
Eur J Pharmacol. 2008 Mar 31;583(1):40-7. Epub 2008 Jan 7.
PMID: 18262520 [PubMed – indexed for MEDLINE]
8:

Shigematsu N, Yamamoto K, Higuchi S, Fukuda T.

Abstract

An immunohistochemical study on a unique colocalization relationship between substance P and GABA in the central nucleus of amygdala.
Brain Res. 2008 Mar 10;1198:55-67. Epub 2008 Jan 3.
PMID: 18243164 [PubMed – indexed for MEDLINE]
9:

Nohe A, Petersen NO.

Abstract

Image correlation spectroscopy.
Sci STKE. 2007 Dec 18;2007(417):pl7.
PMID: 18089858 [PubMed – indexed for MEDLINE]
10:

Bacia K, Schwille P.

Abstract

Practical guidelines for dual-color fluorescence cross-correlation spectroscopy.
Nat Protoc. 2007;2(11):2842-56.
PMID: 18007619 [PubMed – indexed for MEDLINE]

—article of Suzanne, Gif:

Bolte S., and Cordelieres F. (2006) A guided tour into subcellular colocalization analysis in light microscopy. J Microsc. 2006 Dec;224(Pt 3):213-32.

Colocalization and confocal images and imageJ Matlab

The laser scanning confocal microscope (LSCM) generates images of multiple labelled fluorescent samples. Colocalization of fluorescent labels is frequently examined.

Colocalization is usually evaluated by visual inspection of signal overlap or by using commercially available software tools, but there are limited possibilities to automate the analysis of large amounts of data.

–formation

www.picin.u-bordeaux2.fr/Cours/formation_2006/cerner_la_colocalisation_2006.pdf

—————————————————————–

–Colocalization image processing imageJ

Colocalisation analysis is an subject plagued with errors and contention. The literature is full of different methods for colocalisation analysis which probably reflects the fact that one approach does not necessarily fit all circumstances.

Analysis can be considered qualitative or quantitative. However, opinions differ as to which category the different approaches fall!

Qualitative analysis can be thought of as « highlighting overlapping pixels ». Although this is often given as a number (« percentage overlap ») suggesting quantification, the qualitative aspect arises when the user has to define what is considered « overlapping ». The two channels have a threshold set and any areas where they overlap is considered « colocalised ». Qualitative analysis has the benefit of being readily understood with little expert knowledge but suffers from the intrinsic user bias of « setting the threshold ». There are algorithms available which will automate the thresholding without user intervention but these rely on analysis of the image’s histogram which is subject to user intervention during acquisition.

Quantitative analysis removes user bias by analysing all the pixels based on of their intensity (it must be noted that some authors consider this a draw back rather than an advantage due to the intrinsic uncertainty of pixel intensity; see Lachmanovich et al. (2003) J. Microscopy, 212, 122-131). There are a number of coefficients detailed in the literature which can be calculated using ImageJ; each coefficient has it’s strengths and weaknesses and should be thoroughly researched before being used. It is this requirement for the coefficient to be fully understood which is a disadvantage when trying to convey information to research peers who are experts in biology, and not necessarily mathematics.

One key issue that can confound colocalisation analysis is bleed through. Colocalisation typically involves determining how much the green and red colours overlap. Therefore it is essential that the green emitting dye does not contribute to the red signal (typically, red dyes do not emit green fluorescence but this needs to be experimentally verified). One possible way to avoid bleed-through is to acquire the red and green images sequentially, rather than simultaneously (as with normal dual channel confocal imaging) and the use of narrow band emission filters. Single and unlabelled controls must be used to assess bleed-through.

Intensity Correlation Analysis

This plugin generates Mander’s coefficients (see below) as well as performing Intensity Correlation Analysis as described by Li et al. To fully understand this analysis you should read:
Li, Qi, Lau, Anthony, Morris, Terence J., Guo, Lin, Fordyce, Christopher B., and Stanley, Elise F. (2004). A Syntaxin 1, G{alpha}o, and N-Type Calcium Channel Complex at a Presynaptic Nerve Terminal: Analysis by Quantitative Immunocolocalization. Journal of Neuroscience 24, 4070-4081.

It is bundled with WCIF ImageJ and can be downloaded alone here.

reference:

http://www.uhnresearch.ca/facilities/wcif/imagej/colour_analysis.htm

Manders’ Coefficient » (formerly Image Correlator plus<!–[if supportFields]> XE « Image Correlator plus: Wayne Rasband, Tony Collins«  <![endif]–> ” and “Red-Green Correlator” plugins)

This plugin generates various colocalisation coefficients for two 8 or 16-bit images or stacks.

The plugins generate a scatter plots plus correlation coefficients. In each scatter plot, the first (channel 1) image component is represented along the x-axis, the second image (channel 2) along the y-axis. The intensity of a given pixel in the first image is used as the x-coordinate of the scatter-plot point and the intensity of the corresponding pixel in the second image as the y-coordinate.

The intensities of each pixel in the “Correlation Plot” image represent the frequency of pixels that display those particular red/green values. Since most of you image will probably be background, the highest frequency of pixels will have low intensities so the brightest pixels in the scatter plot are in the bottom left hand corner – i.e. x~ zero, y ~ zero. The intensities in the “Red-Green correlation plot” image represent the actual colour of the pixels in the image.

Mito-DsRed; ER-EGFP

Pearson’s correlation (R)=0.34

Overlap coefficient (R)=0.40

Nred ÷ Ngreen pixels=0.66

Colocalisation coefficient for red (Mred)=0.96

Colocalisation coefficient for green (Mgreen)=0.49

TMRE (red) plus Mito-pericam (Green)

Pearson’s correlation Rr=0.93

Overlap coefficient R=0.94

Nred ÷ Ngreen pixels=0.93

Colocalisation coefficient (red) Mred=0.99

Colocalisation coefficient (green) Mgreen=0.98

Both plugins generate various colocalisation coefficients: Pearson’s (Rr), Overlap (R) and Colocalisation (M1, M2) See Manders, E.E.M., Verbeek, F.J. & Aten, J.A. ‘Measurement of co-localisation of objects in dual-colour confocal images’,  (1993) J. Microscopy, 169, 375-382. See tutorial sheet ‘Colocalisation’ for details. The threshold is also reported (0,0 means no threshold was used).

Colocalisation Test

When a coefficient is calculated for two images, it is often unclear quite what this means, in particular for intermediate values. This raises the following question: how does this value compare with what would be expected by chance alone?

There are several approaches that can be used to compare an observed coefficient with the coefficients of randomly generated images. Van Steensel (3) adopted an approach where the observed colocalisation between channel 1 and channel 2 was compared to colocalisation between channel 1 and a number of channel 2 images that had been translated (i.e. displaced by a number of pixels) in increments along the image’s X-axis. Fay et al (4) extended this approach by translating channel 2 in 5-pixel increments along the X- and Y-axis (i.e., –10, –5, 0, 5, and 10) and ± 1 slices in the Z-axis. This results in 74 randomisations (plus one original channel 2). The observed correlation was compared to these 74 and considered significant if it was greater than 95% of them.

Costes et al. (5) subsequently adopted a different approach, based on “scrambling” channel 2. The original channel 1 image was compared to 200 “scrambled” channel 2 images; the observed correlations between channel 1 and channel 2 were considered significant if they were greater than 95% of the correlations between channel 1 and scrambled channel 2s.

Costes’ scrambled images were generated by randomly rearranging blocks of the channel-2 image. The size of these blocks was chosen to equal the point spread function (PSF) of the image.

An approximation of Costes’ approach is used by Bitplane’s Imaris and also the Colocalisation Test plugin. For Imaris, a white noise image is smoothed with a Gaussian filter the width of the image’s PSF. The Colocalisation Test plugin generates a randomized image by taking random pixels from the channel-2 image; it then smoothes the image with a Gaussian filter, which is again the width of the image’s PSF.

The Colocalisation Test plugin calculates Pearson’s correlation coefficient for the two selected channels (Robs) and compares this to Pearson’s coefficients for channel 1 against a number of randomized channel-2 images (Rrand).

–Colocalization image processing matlab:

doi:10.1016/S0169-2607(03)00071-3

Automated high through-put colocalization analysis of multichannel confocal images

M. Kreft , I. Milisav , M. Potokar and R. Zorec

Lab. Neuroendocrinology-Molecular Cell Physiology, Inst. Pathophysiology, Medical Faculty, Zaloska 4, 1000 Ljubljana and Celica Biomed. Sciences Center, Stegne 21, 1000, Ljubljana, Slovenia

accepted 20 April 2003.

Available online 15 July 2003.

We developed a simple tool using Matlab to automate the colocalization procedure and to exclude the biased estimations resulting from visual inspections of images. The script in Matlab language code automatically imports confocal images and converts them into arrays. The contrast of all images is uniformly set by linearly reassigning the values of pixel intensities to use the full 8-bit range (0–255). Images are binarized on several threshold levels. The area above a certain threshold level is summed for each channel of the image and for colocalized regions. As a result, count of pixels above several threshold levels in any number of images is saved in an ASCII file. In addition Pearson’s r correlation coefficient is calculated for fluorescence intensities of both confocal channels. Using this approach quick quantitative analysis of colocalization of hundreds of images is possible. In addition, such automated procedure is not biased by the examiner’s subject visualization.

kreft-2004-colocalization


I MOVED THIS BLOG FROM WORDPRESS TO BLOGGER. Ce blog est à
ex-ample.blogspot.com

Blog Stats

  • 226 573 hits

Meilleurs clics

  • Aucun

localization

Flickr Photos

Mai 2024
L M M J V S D
 12345
6789101112
13141516171819
20212223242526
2728293031